Sealcon #: CD22MA-FX
Cable Range: 0.39" - 0.55" (10 to 14 mm)
Material: Nickel Plated Brass
Hummel: HSK-M-EMV-D-Ex
Hummel #: 1.636.2000.50
Need Technical Assistance?
Give our technical sales team a call
(303) 699-1135 | (800) 456-9012
Give our technical sales team a call
(303) 699-1135 | (800) 456-9012
Hole Diameter (A) | 0.89" (22.5 mm) |
---|---|
Body Length (B) | 1.22" (31 mm) |
Thread Length (D) | 0.24" (6 mm) |
Wrench Flat (F1) | 0.94" (24 mm) |
Suggested Clearance Hole for Non-Threaded Mounting
PDF DOWNLOADS
Catalog Page-
Features
Cable glands of the HSK-EMC-Ex- series have been designed for standard applications in hazardous locations type “e” according to EN 60079-0 and 60079-7
- Machine, apparatus and plant equipment
- Measuring control and feedback systems
- Control cabinets
- Railroad cars and vehicles
- Industrial installations
- Marine
- Off-shore
and in all installations where excellent performance, fire resistance and no twisting or torquing of the cable are critical
-
MaterialsOperating Temperature
-60C° to 95C° (-76°F to 203°F) APPROVALS