M12 Power Technical Info
Mechanical Data
Housing: | Brass / Die Cast INOX AISI 316 L TPU (moulded versions) |
Housing Surface: | Nickel plated other surfaces upon request |
Inserts (For Contacts): | PBT Fire protection class V-0 |
Contacts: | Copper alloy / Brass |
Contact Surface: | Brass Contact area gold plated |
Minimum Mating Cycles: | > 100 |
Seals / O-Rings: | (FKM / FPM) / Buna-n / HNBR |
Temperature Range: | -40° C-125° C (-40 °F-257 °F) (K + L) -40 °C-85 °C (-40 °F-185 °F) (s + t) |
Protection: | IP 67 / IP 69 K |
Cable Diameter Range: | 3-11 mm (.11-.43″) |
Electrical Data
Coding | S | T | K | L |
---|---|---|---|---|
Colors | black | dark grey | blue | grey |
Number of positions | 4 (3 + PE) | 4 | 5 (4 + PE) | 5 (4 + FE) |
Terminal Cross section [mm2] AWG | 0.5-1.5 AWG 20-16 | 0.5-1.5 AWG 20-16 | 0.75-2.5 AWG 18-14 | 0.75-2.5 AWG 18-14 |
Nominal voltage 2 [V~] degree of protection 3 4 | 12 | 12 | 16 | 16 |
Test Voltage (Breakdown Voltage) [V~] | 630 | 63 | 630 | 63 |
Insulation Resistance [MΩ] | > 102 | > 102 | > 102 | > 102 |
Max. Contact Resistance [mΩ] | < 3 | < 3 | < 3 | < 3 |
*Degree of Protection
Potential dirt accumulation of a disconnected connector in a certain environment.
*Degree of Protection 2
No permanent conductive dirt accumulation will occur. Temporary conductive dirt accumulation, such as condensation, is possible. Typical for households, offices, laboratories and test labs.
*Degree of Protection 3
Conductive, as well as dry non-conductive dirt accumulation can occur. It can be temporarily conductive due to condensation. Typical for industrial and factory environments.