M23 PoE / Profinet Technical Info
Mechanical Data
Housing: | Copper-Zinc Alloy, Die Casting |
Housing Surface: | Nickel Plated Brass |
Inserts (For Contacts): | Thermoplastic Polyamid PA 6 (Nylon 6/6), PBT Fire protection class V-0 |
Contacts: | Brass Alloy |
Contact Surface at point of Contact: | Nickel and gold plated (0,25µm Au) |
Minimum Mating Cycles: | > 1000 |
Seals / O-Rings: | Buna-N standard, optional FPM |
Temperature Range: | -40°F to 257°F (-40°C to 125°C) |
Type of Contacts: | Crimp, dip solder (PCB) |
Protection: | IP 67 per EN 60529 (connected), Type NEMA 4x |
Cable Diameter Range: | .43 - .67" (11 - 17 mm) |
Electrical Data
Number of Positions | 20 (4 x 2 + 12) | |
---|---|---|
Number of Contacts | 4×2 | 12 |
Contact Ø (mm) | 0.6 | 1 |
AWG [mm²] | 0.08 – 0.34 | 0.14 – 1 / 1.5 |
Nominal Current [A] | 2 | 8 |
Nominal Voltage [V~] Degree of Protection 2 | 160 | 320 |
Nominal Voltage [V~] Degree of Protection 3 | 60 | 160 |
Test Voltage (Breakdown Voltage) [V~] | 500 | 1500 |
Insulation Resistance [MΩ] | > 106 | > 106 |
Max. Contact Resistance [mΩ] | 3 | 3 |
Impedance [Ω] at 100MHz) | 100 | – |
*Degree of Protection
Potential dirt accumulation of a disconnected connector in a certain environment.
*Degree of Protection 2
No permanent conductive dirt accumulation will occur. Temporary conductive dirt accumulation, such as condensation, is possible. Typical for households, offices, laboratories and test labs.
*Degree of Protection 3
Conductive, as well as dry non-conductive dirt accumulation can occur. It can be temporarily conductive due to condensation. Typical for industrial and factory environments.