Mechanical Data

Housing:Copper-Zinc Alloy, Die Casting & Aluminum Alloy
Housing Surface:Nickel Plated Brass, Other Surfaces Upon Request
Inserts (For Contacts):Thermoplastic Polyamid PA 6 (Nylon 6/6), PBT Fire protection class V-0
Contacts:Brass Alloy
Contact Surface at point of Contact:Nickel and gold plated (0,25µm Au)
Minimum Mating Cycles:> 1000
Seals / O-Rings:Buna-N standard, optional FPM
Temperature Range:-40°F to 257°F (-40°C to 125°C)
Type of Contacts:Crimp, dip solder (PCB)
Protection:IP 67 / IP 69 K per EN 60529 (connected), NEMA 4x
Cable Diameter Range:.08 - .43" (2 - 11 mm)

Electrical Data

Number of Positions3 (3×1)3 (3×2)4+3+PE (320V)4+3+PE (630V)
Number of Contacts334444
Contact Ø (mm)120.81.60.81.25
AWG [mm2]0.08-0.340.34-1.50.08-0.340.34-1.5
Nominal Current [A]820516516
Nominal Voltage2 [V~] Degree of Protection 32400630160320300630
Test Voltage (Breakdown Voltage) [V~]250025001500250015002500
Insulation Resistance [MΩ]> 1010> 1010> 1010> 1010
Max. Contact Resistance [mΩ]33333

Electrical Data

Number of Positions1012+318
Number of Contacts1012318
Contact Ø (mm)10.81.250.8
AWG [mm2]0.14-0.750.08-.340.5-1.50.08-0.34
Nominal Current [A]83103
Nominal Voltage2 [V~] Degree of Protection 2*2306016060
Nominal Voltage2 [V~] Degree of Protection 3*160246024
Test Voltage (Breakdown Voltage) [V~]1500150025001500
Insulation Resistance [MΩ]> 106> 1010> 1010
Max. Contact Resistance [mΩ]3333

*Degree of Protection
Potential dirt accumulation of a disconnected connector in a certain environment.

*Degree of Protection 2
No permanent conductive dirt accumulation will occur. Temporary conductive dirt accumulation, such as condensation, is possible. Typical for households, offices, laboratories and test labs.

*Degree of Protection 3
Conductive, as well as dry non-conductive dirt accumulation can occur. It can be temporarily conductive due to condensation. Typical for industrial and factory environments.